ROTARY SCREW COMPRESSION
Compression Solutions for Sour Gas Recovery and Reinjection
Altara’s compression line includes rotary screw packages designed to handle sour gas safely and efficiently.
Every unit is sour-rated, VFD-controlled, and built for remote operation.
Specs & Range
- 100 HP – 500 HP Units
- Pressures up to 250 psig
- Sour service materials and seal packages
- Integrated automation with remote monitoring
Applications
- Tank vapor recovery
- Sour-gas removal from SRTs (Sulfur Recovery Towers)
| HP Group | Typical Driver Type | Approx kVA | Approx Full-Load Amps | Design Suction Range (psig) | Design Discharge Range (psig) | Expected Capacity (MMSCFD) | H₂S Capability | Notes |
|---|---|---|---|---|---|---|---|---|
| 100 HP | Electric | ~165–170 kVA | ~200 A | 0–5 | 100–200 | 0.20–0.60 | Yes | Bread-and-butter low-rate units |
| 200 HP | Electric | ~333 kVA | ~400 A | 0–15 | 200–350 | 0.60–1.20 | Yes | High-flash crude / high vapor |
| 300 HP | Electric | ~500 kVA | ~600 A | 0–20 | 250–500 | 1.00–1.80 | Yes | VRU + small booster service |
| 400 HP | Electric | ~665–670 kVA | ~800 A | 0–25 | 200–400 | 1.00–2.40 | Yes | Multi-pad VRU header service |
| 500 HP | Electric | ~830–835 kVA | ~1000 A | 0–35 | 300–700 | 2.00–4.00 | Yes | VRU + transmission gas capability |
50 HP – Micro VRU
Driver: Electric
Approx kVA: ~80–85 kVA
Full-Load Amps: ~100 A
Suction Range: 0–3 psig
Discharge Range: 50–120 psig
Expected Capacity: 0.05–0.20 MMSCFD
H₂S Capability: Yes (limited)
Notes: Small well-pad vapor-only
100 HP – Small VRU
Driver: Electric
Approx kVA: ~165–170 kVA
Full-Load Amps: ~200 A
Suction Range: 0–5 psig
Discharge Range: 100–200 psig
Expected Capacity: 0.20–0.60 MMSCFD
H₂S Capability: Yes (some)
Notes: Bread-and-butter low-rate units
150 HP – Standard VRU
Driver: Electric
Approx kVA: ~250 kVA
Full-Load Amps: ~300 A
Suction Range: 0–10 psig
Discharge Range: 150–250 psig
Expected Capacity: 0.40–1.00 MMSCFD
H₂S Capability: Yes
Notes: Strong mid-rate sour VRU
200 HP – High-Cap VRU
Driver: Electric
Approx kVA: ~333 kVA
Full-Load Amps: ~400 A
Suction Range: 0–15 psig
Discharge Range: 200–350 psig
Expected Capacity: 0.60–1.20 MMSCFD
H₂S Capability: Yes
Notes: High-flash crude / high vapor
300 HP – Hybrid VRU / Booster
Driver: Electric
Approx kVA: ~500 kVA
Full-Load Amps: ~600 A
Suction Range: 0–20 psig
Discharge Range: 250–500 psig
Expected Capacity: 1.00–1.80 MMSCFD
H₂S Capability: Yes
Notes: VRU + small booster service
400 HP – Large VRU
Driver: Electric
Approx kVA: ~665–670 kVA
Full-Load Amps: ~800 A
Suction Range: 0–25 psig
Discharge Range: 200–400 psig
Expected Capacity: 1.00–2.40 MMSCFD
H₂S Capability: Yes
Notes: Multi-pad VRU header service
500 HP – Large VRU / High-Pressure Gas
Driver: Electric
Approx kVA: ~830–835 kVA
Full-Load Amps: ~1000 A
Suction Range: 0–35 psig
Discharge Range: 300–700 psig
Expected Capacity: 2.00–4.00 MMSCFD
H₂S Capability: Yes
Notes: VRU + transmission gas capability
Our Core Offerings