VRU & GAS LIFT COMPRESSION
Compression Solutions for Sour Gas Recovery and Reinjection
Altara’s compression line includes VRUs and gas lift packages designed to handle sour gas safely and efficiently.
Every unit is NACE-rated, VFD-controlled, and built for remote operation.
Specs & Range
- Need to list out our typical sizes (100 HP – 500 HP Units)
- Pressures up to 250 psig
- Sour service materials and seal packages
- Integrated automation with remote monitoring
Applications
- Tank vapor recovery
- Gas lift systems
- Sour-gas removal from SRTs (Sulfur Recovery Towers)
| HP Group | Typical Driver Type | Approx kVA | Approx Full-Load Amps | Design Suction Range (psig) | Design Discharge Range (psig) | Expected Capacity (MMSCFD) | H₂S Capability | Notes |
|---|---|---|---|---|---|---|---|---|
| 100 HP | Electric | ~165–170 kVA | ~200 A | 0–5 | 100–200 | 0.20–0.60 | Yes (some) | Bread-and-butter low-rate units |
| 200 HP | Electric | ~333 kVA | ~400 A | 0–15 | 200–350 | 0.60–1.20 | Yes | High-flash crude / high vapor |
| 300 HP | Electric | ~500 kVA | ~600 A | 0–20 | 250–500 | 1.00–1.80 | Yes | VRU + small booster service |
| 400 HP | Electric | ~665–670 kVA | ~800 A | 0–25 | 200–400 | 1.00–2.40 | Yes | Multi-pad VRU header service |
| 500 HP | Electric | ~830–835 kVA | ~1000 A | 0–35 | 300–700 | 2.00–4.00 | Yes | VRU + transmission gas capability |
50 HP – Micro VRU
Driver: Electric
Approx kVA: ~80–85 kVA
Full-Load Amps: ~100 A
Suction Range: 0–3 psig
Discharge Range: 50–120 psig
Expected Capacity: 0.05–0.20 MMSCFD
H₂S Capability: Yes (limited)
Notes: Small well-pad vapor-only
100 HP – Small VRU
Driver: Electric
Approx kVA: ~165–170 kVA
Full-Load Amps: ~200 A
Suction Range: 0–5 psig
Discharge Range: 100–200 psig
Expected Capacity: 0.20–0.60 MMSCFD
H₂S Capability: Yes (some)
Notes: Bread-and-butter low-rate units
150 HP – Standard VRU
Driver: Electric
Approx kVA: ~250 kVA
Full-Load Amps: ~300 A
Suction Range: 0–10 psig
Discharge Range: 150–250 psig
Expected Capacity: 0.40–1.00 MMSCFD
H₂S Capability: Yes
Notes: Strong mid-rate sour VRU
200 HP – High-Cap VRU
Driver: Electric
Approx kVA: ~333 kVA
Full-Load Amps: ~400 A
Suction Range: 0–15 psig
Discharge Range: 200–350 psig
Expected Capacity: 0.60–1.20 MMSCFD
H₂S Capability: Yes
Notes: High-flash crude / high vapor
300 HP – Hybrid VRU / Booster
Driver: Electric
Approx kVA: ~500 kVA
Full-Load Amps: ~600 A
Suction Range: 0–20 psig
Discharge Range: 250–500 psig
Expected Capacity: 1.00–1.80 MMSCFD
H₂S Capability: Yes
Notes: VRU + small booster service
400 HP – Large VRU
Driver: Electric
Approx kVA: ~665–670 kVA
Full-Load Amps: ~800 A
Suction Range: 0–25 psig
Discharge Range: 200–400 psig
Expected Capacity: 1.00–2.40 MMSCFD
H₂S Capability: Yes
Notes: Multi-pad VRU header service
500 HP – Large VRU / High-Pressure Gas
Driver: Electric
Approx kVA: ~830–835 kVA
Full-Load Amps: ~1000 A
Suction Range: 0–35 psig
Discharge Range: 300–700 psig
Expected Capacity: 2.00–4.00 MMSCFD
H₂S Capability: Yes
Notes: VRU + transmission gas capability
Our Core Offerings